SECTION2 PLAN YOUR INSTALLATION
C. TYPICAL SOLDERED COPPER (OR PVC) IN AND OUT PIPES TO SOFTENER
HIGH PERFORMANCE VALVE MODELS
IN AND OUT PLUMBING USING
A 3-VALVE BYPASS
s .%"----""----.._ Main_e
OPTWAT_R__ " .
_R
shutoff valves,
FITTINGS ]
90 ° elbow (4) ]
tee (2) /
1" NPT sweat adaptor (2) | OUT IN
pipe (as required) -- J 1
/(..,.__/ "threaded adaptor/
.--__ _'_ - o-ring seal /' 2ncO[uedae_h
<-_. __
\ To connect to 1-1/4"
copper household
_. plumbing _
Available from Sears
see Owner's Manual for part numbers
NOTE:
For plumbing connection, buy 2
sweat adaptors and plumb directly to
the inlet-outlet adaptors or bypass
valve. Threads on the inlet-outlet
adaptors and bypass valve are 1" NPT.
CAUTION:
DO ALL SOLDERING BEFORE
CONNECTING SWEAT ADAPTOR
TO INLET-OUTLET ADAPTORS
OR BYPASS VALVE.
IN AND OUT PLUMBING USING
SEARS BYPASS VALVE (included)
OUT
/
/
outside
faucets
FITTINGS
REQUIRED, NOT
IDENTIFIED
90 ° elbow (2)
1" NPT sweat adaptor (2)
pipe (as required)
\
threaded adaptor
o-ring seal /
cli J
P 2 of each
included
\
\
\
Bypass Valve
(included with some
models)
//
I \
/ \
To connect to 1-1/4"
copper household /
plumbing /
\ f
Available from Sears
see Owner's Manual for part numbers
2-4
High Performance Valve