Kenmore 153.31702 Water Heater User Manual


 
Troubleshooting Guide
Start Up Conditions
THERMAL EXPANSION
Water supply systems may, because of such events as high line
pressure, frequent cut-off_, the effects of water hammer among
others, have installed devices such as pressure reducing valves,
check valves, back flow preventers, etc._to control these types of
_roblems. When these devices are not equipped with an internal
y-pass, and no other measures are taken, the devices cause the
water system to be dosed. As water is heated, it expands (ther-
mal expansion) and dosed systems do not allow for the expan-
sion of heated water.
The water within the water heater tank expands as it is heated and
increases the pressure of the water system. If the relieving point of
the water heater's temperature-pressure relief valve is reached, the
valve will relieve the excess pressure. The temperature-pressure
relief valve is not intended for the constant relief of thermal
expansion. This is an unacceptable condition and must be cor-
rected.
It is recommended that any devices installed which could create a
closed system have a by-pass and/or the system have an expan-
sion tank to relieve the pressure built by thermal expansion.
Thermal expansion tanks are available from Sears stores and
through the Sears Service Centers. Contact the local plumbing
inspector, water supplier and/or the Sears Service Center for
assistance in controlling these situations.
Thermal Expansion Tank Specifications
Model "I_tnkCapacity Dimensions in Inches ]Pipe Fitting
Number In Gallons Diameter [ Length [ On "lhnk
153.331020 2 8 inches ]12_ inches] _" Male
Expansion Tank Sizing Chart
Expansion Inlet*
_Ihnk Water
Capacity Pressure
Needed 40-80psi
Water Heater Capacity (Gallons)
2 4 6 10 19.9
2 2 2 2 2
HOT COLD
WATER HEATER
COLD WATER
INLET FITTING
MOT COLD
WATER HEATER (3)
COLD WATER PRESSURE
,INLET FITTING REDUCING
VALVEWITH
BY-PASS
O)
EXPANSION
TANK
(z)
PRESSUREGAUGE
WATER
SHUTOFF
RECOMMENDED INSTALLATION
(VERTICAL MOUNTING)
FLOOR,CEILING
JOIST,ETC.
STRAPPING
(0
EXPANSION
TANK
0)
PRESSURE
REDUCING INLET COLD
VALVEWITH WATER
BY-PASS SHUTOFF
(2)
PRESSUREGAUGE
ALTERNATERECOMMENDED
INSTALLATION
(HORIZONTAL MOUNTING)
*Highest recorded inlet water pressure in a 24 hour period or
regulated water pressure.
NOTE= Expansion tanks are pre-charged with a 40 psi air
charge. If the inlet water pressure is higher than 40 psi, the
expansion tank's air pressure must be adjusted to match that
pressure, but must not be higher than 80 psi.
STRANGE SOUNDS
Possible noises due to expansion and contraction of"some metal
_arts during periods of heat-up and cool-down do not represent
armful or dangerous conditions.