Jotul Gas Stove Stove User Manual


 
4
GF 400 BV Sebago
Specifications
The Jøtul GF400 BV Sebago is a atmospherically-
vented gas fireplace heater designed only for
vertical venting directly to the outside of the house,
using listed, Type B-vent pipe.
Input Rates
Natural Gas
40,000 BTU/hr. maximum input
22,000 BTU/hr. minimum input
Propane
40,000 BTU/hr. maximum input
20,000 BTU/hr. minimum input
Inlet Pressure: MIN MAX
Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)
Propane: 12.0 WC (2.99 kPa) 14.9 WC (3.71 kPa)
Manifold Pressure: MIN MAX
Natural Gas: 1.2 WC (.30 kPa) 3.8 WC (.95 kPa)
Propane: 2.9 WC (.722 kPa) 11.0 WC (2.74 kPa)
Piezo Ignitor / Standing Pilot
Suggested Tools for
Installation and Service
External regulator (for Propane only)
Piping which complies with local code
Manual shutoff valve (T-Handle in Massachusetts)
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10 mm open end wrench
1/2”, 7/16” open end wrench or deep socket
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
4 mm allen wrench
Gloves
Safety glasses
Torx T20 screwdriver
Leak test solution
Reciprocating Saw
Power Drill
THIS FIREPLACE IS SHIPPED FROM THE FACTORY
FOR USE WITH NATURAL GAS ONLY. FOR USE WITH
PROPANE, THE APPLIANCE MUST FIRST BE
CONVERTED USING #156003 FUEL CONVERSION KIT
PROVIDED. CONVERSION SHOULD BE MADE
BEFORE THE APPLIANCE IS INSTALLED. SEE PG. 11.
With Short Legs, reduce height by 2 1/4” ( 51 mm)