Jotul Gas Stove Stove User Manual


 
20
THIS BLOWER MUST BE
ELECTRICALLY GROUNDED IN
ACCORDANCE WITH LOCAL CODES
OR, IN THE ABSENCE OF LOCAL
CODES, WITH THE CURRENT ANSI/
NFPA 70, NATIONAL ELECTRICAL
CODE OR CSA C22.1-CANADIAN
ELECTRICAL CODE.
THIS UNIT IS SUPPLIED WITH A
THREE-PRONG (GROUNDING)
PLUG FOR PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE
PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED THREE-
PRONG RECEPTACLE. DO NOT
CUT OR REMOVE THE GROUNDING
PRONG FROM THE PLUG.
ALWAYS DISCONECT THE POWER
SUPPLY WHEN PERFORMING ANY
SERVICE ON THE FIREPLACE
INSERT.
Optional Blower # 156000
Connect the gas supply line to the stove,
before installing the Blower.
Use a 90° Elbow off the control valve to create
clearance required for the blower installation.
1. Unpack and check the contents of the blower kit.
Contact your dealer if any damage is evident or
parts are missing. See fig. 33.
2. Attach the Snapstat Bracket to the studs located in
the middle of the firebox floor using the two M6
hex nuts and a 10 mm wrench. See fig. 34.
3. Attach the Blower Bracket to the stove using the
two M6 flange head hex bolts as shown in fig. 34.
4. Attach the Duct Deflectors using the two #7 x 1/2”
screws together with the finger guard mounting
screws already in place. See #7 and #11 in fig. 33.
5. Install the Blower with the duct openings oriented
up and forward. See fig. 35. Feed the wire harness
through the bracket opening and secure the blower
to the bracket with the wingscrew.
6. Attach either Snapstat wire connector to either
Snapstat terminal. See fig. 35.
7. Install the Snapstat by sliding it all the way into the
slot in the bottom of the Snapstat Bracket as shown
in figs. 34 and 35.
8. Connect the male wire harness connector to the
female wire harness connector already installed in
the stove. See fig. 35.
9. Connect power cord to outlet.
Figure 34. Attach Snapstat and Blower Brackets.