INPUT CIRCUIT BREAKER
TABLE B-3: Input Breaker Ampacity (Standard KAIC)
Input Voltages
KVA
120 Vac 240 V/ or 208V
3
50 Amps, 120 VAC,
1 Pole, 14 KAIC
OLP P/N: 2025-784
30 Amps, 240 VAC,
2 Pole, 14 KAIC
OLP P/N: 2025-790
5
70 Amps, 120 VAC,
1 Pole, 14 KAIC
OLP P/N: 2025-997
40 Amps, 240 VAC,
2 Pole, 10 KAIC
OLP P/N: 2025-791
7.5 N/A
60 Amps, 240 VAC,
2 Pole, 10 KAIC
OLP P/N: 2025-793
10 N/A
70 Amps, 240 VAC,
2 Pole, 10 KAIC
OLP P/N: 2025-794
12.5 N/A
90 Amps, 240 VAC,
2 Pole, 10 KAIC
OLP P/N: 2025-796
15 N/A
125 Amps, 240 VAC,
2 Pole, 65 KAIC
OLP P/N: 2025-759
TABLE B-4: Input Breaker Ampacity (hIGH KAIC)
Input Voltages
KVA
120 Vac 240 Vac or 208VAC
3
50 Amps, 120 VAC,
1 Pole, 42 KAIC
OLP P/N: 2025-800
30 Amps, 240 VAC,
2 Pole, 65 KAIC
OLP P/N: 2025-764
5
70 Amps, 120 VAC,
1 Pole, 42 KAIC
OLP P/N: 2025-998
40 Amps, 240 VAC,
2 Pole, 65 KAIC
OLP P/N: 2025-766
7.5 N/A
60 Amps, 240 VAC,
2 Pole, 65 KAIC
OLP P/N: 2025-768
10 N/A
70 Amps, 240 VAC,
2 Pole, 65 KAIC
OLP P/N: 2025-769
12.5 N/A
90 Amps, 240 VAC,
2 Pole, 65 KAIC
OLP P/N: 2025-771
15 N/A
125 Amps, 240 VAC,
2 Pole, 65 KAIC
OLP P/N: 2025-759