Hunter Fan R410A Air Conditioner User Manual


 
-
40
-
12
Function No. A
(Example) If the upper limit is set at 28˚C
Function Contents B Setting Contents C
TEMP RANGE SET
DISP CHANGE
NO DISP CHANGE
Control Contents
The remote controller’s display and sent
data upper limit changes to 28°C.
The remote controller’s display upper
limit remains at 30ºC and only the upper
limit of the sent data is changed to 28°C.
(d) Changing the remote controllers temperature setting range
1) The temperature setting range of the remote controller can be changed.
Through remote controller button operations, the upper limit and lower limit set temperature values can be changed
individually.
During heating operation, the changed upper limit value becomes valid and at times other than during heating operation,
(during cooling, dehumidification, auto and fan operation), the changed lower limit value becomes valid.
Range of Possible Changes
Upper Limit Value: 22~30ºC (valid during heating) Lower Limit Value: 18 ~ 26ºC (valid at times other than during
heating)
2) Operation
a) With the remote controller in the stopped state, press the
SET and
MOFDE
buttons simultaneously for 3 seconds or
longer. The display will changed from
SELECT ITEM
SET FUNCTION SET
b) Press the
button once. The display will change to TEMP RANGE
.
c) Press the
SET
button to enter the temperature range setting mode.
d) Using the
or
button, select Hi LIMIT SET
or Lo LIMIT SET
, the press the
SET
button.
e) If Hi LIMIT SET is selected,
1 The display changes from
SET UP Hi LIMIT 22ºC (flashing).
2 Using the
button, select the upper limit value. Display example: Hi LIMIT 22ºC
(flashing)
3 Press the SET
button to fix the setting. Display example: Hi LIMIT 22ºC (lighted up)
f) If Lo LIMIT SET is selected,
1 The display changes from
SET UP Lo LIMIT 26ºC
(flashing).
2 Using the
button, select the upper limit value. Display example: Lo LIMIT 26ºC
(flashing)
3 Press the SET button to fix the setting. Display example: Lo LIMIT 26ºC (lighted up)
g) Press the ON/OFF button to end the setting procedure.
(The procedure also ends if the ON/OFF button is pressed during the setting operation. However, settings which have
not been fixed become invalid, so exercise caution.)
If the
RESET
button is pressed during a setting operation, the display returns to the previously displayed setting screen.
However, settings which have not been fixed become invalid, so exercise caution.
* If NO DISP CHANGE is selected in No. 12, TEMP RANGE SET of the remote controllers functions, No. 1 of
the function setting modes, the remote controllers display does not change even if the temperature range has been
changed.