Hunter Fan R410A Air Conditioner User Manual


 
-
37
-
(2) Setting functions using the remote controller
(a) The factory settings of this unit's functions are as follows: If you want to charge a setting, follow the
procedure found in the installation manual and set to your desired setting.
For the method of setting, please refer to the installation manual of a remote control unit.
1 Remote controller unit functions (
FUNCTION )
2 Indoor unit functions (I/U FUNCTION
)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
Factory
setting
GRILLE SET
AUTO RUN SET
TEMP S/W
MODE S/W
ON/OFF S/W
FANSPEED S/W
LOUVER S/W
TIMER S/W
SENSOR S/W
VENTI SET
TEMP RANGE SET
I/U FA SPEED
MODEL TYPE
EXTERNAL CONTROL SET
ERROR DISP SET
POSITION
°C/°F SET
INVALID
50Hz AREA ONLY
60Hz AREA ONLY
AUTO RUN ON
AUTO RUN OFF
VALID
INVALID
VALID
INVALID
VALID
INVALID
VALID
INVALID
VALID
INVALID
VALID
INVALID
INSENSOR OFF (Invalid)
SENSOR ON (Valid)
INVALID
VALID
NO VENTI
VENTI LINK SET
NO VENTI LINK
DISP CHARGE
NO DISP CHARGE
3 FAN SPEED
2 FAN SPEED
1 FAN SPEED
HEAT PUMP
COOLING ONLY
INDIVIDUAL OPERATION
SAME OPERATION FOR ALL UNITS
ERROR DISP
NO ERROR DISP
FIX (1 OF 4) (4 position stop)
IN MOTION (Free stop)
°C
°F
Grille lift
panel setting
Remote control
sensor setting
Indoor unit
fan speed setting
ON/OFF
Louver
control setting
ON/OFF
ON/OFF
01
03
04
05
06
07
08
09
10
Function
number A
Factory
setting
Hi CEILING SET
FILTER SIGN SET
POSITION
EXTERNAL INPUT SET
ROOM TEMP OFF SET
FAN CONTROL
FREEZE PREVENT TEMP
FREEZE PREVENT CONTROL
(Heating room temperature off set)
Heating
fan control
Louver control
setting
STANDARD (Mild mode)
Hi CEILING 1
(Powerful mode)
NO DISPLAY
AFTER 180H
AFTER 600H
AFTER 1000H
1000HSTOP
FIX (1 OF 4) (4 positiion stop)
IN MOTION (Free stop)
LEVEL INPUT
PULSE INPUT
NORMAL OPERATION
VALID
NORMAL OPERATION
TEMP SHIFT +3˚C
LOW FAN
STOPLOW FAN (Intermittent operation)
TEMP Hi
TEMP Lo
FAN CONTROL ON
FAN CONTROL OFF
Function description
B
Setting
C
Function
number A
Function description
B
Setting
C
()
()
()
()
POWER FAILURE
COMPENSATION SET
()
()
OPERATION PERMISSION
PROHIBITED
Notes(1)
(2)
Setting marked with [] are the default setting.
Setting marked with [
*
] are those that are set automatically
according to an indoor unit or an outdoor unit connected.
Please check default settings with the indoor unit's installation
manual.
Notes(1)
(2)
(3)
Setting marked with [] are the default setting.
Setting marked with [
*
] are those that are set automatically
according to an indoor unit or an outdoor unit connected.
Please check default settings with the indoor unit's installation
manual.
When Item 17 : POSITION is changed, please also
change Item 04 POSITION setting found in
Indoor unit functions.
*
*
*
*
*
*
*
*