Summary Of Audible Notification
(Alpha Display Keypads)
SOUND CAUSE DISPLAY
LOUD,
INTERRUPTED*
Keypad & External
FIRE ALARM
FIRE
is displayed; descriptor of zone in alarm is
displayed.
LOUD,
CONTINUOUS*
Keypad & External
BURGLARY/AUDIBLE EMERGENCY
ALARM
ALARM
is displayed; descriptor of zone in alarm is
also displayed.
ONE SHORT BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY
a.
DISARMED/READY TO ARM
is displayed.
b. The number and descriptor of the open protection
zone is displayed.
c. Numbers and descriptors of the bypassed
protection zones are displayed (One beep is heard
for each zone displayed). Subsequently, the
following is displayed:
DISARMED BYPASS Ready
to Arm
ONE SHORT BEEP
(once every 15
sec.) Keypad only
SYSTEM IS IN TEST MODE Opened Zone identifications will appear.
TWO SHORT BEEPS
(once every 5 sec.)
Keypad only
SYSTEM IS ABOUT TO
AUTOMATICALLY EXIT TEST
MODE
Opened Zone identifications will appear.
ONE BEEP
(every 60 sec.)
Keypad only
LOW BATTERY AT A TRANSMITTER
LO BAT
displayed with description of transmitter.
TWO SHORT BEEPS
Keypad only
ARM AWAY OR MAXIMUM
ARMED AWAY or ARMED MAXIMUM
is displayed.
Red ARMED indicator is lit.
THREE SHORT
BEEPS
Keypad only
a. ARM STAY OR INSTANT
b. ZONE OPENED WHILE SYSTEM
IS IN CHIME MODE.
c. ENTRY WARNING**
a.
ARMED STAY ZONE BYPASSED
or
ARMED
INSTANT ZONE BYPASSED
is displayed. Red
ARMED indicator is lit.
b.
CHIME
displayed, descriptor of open protection
zone will be displayed if the [ ] key is pressed.
c.
DISARM SYSTEM OR ALARM WILL OCCUR
is
displayed.
RAPID BEEPING
Keypad only
a. TROUBLE
b. AC POWER LOSS ALERT***
c. MEMORY OF ALARM
a.
CHECK
displayed. Descriptor of troubled protection
zone is displayed.
b.
AC LOSS
displayed (may alternate with other display
that may be present).
c.
FIRE
or
ALARM
is displayed; descriptor of zone in
alarm is displayed.
SLOW BEEPING
Keypad only
a. ENTRY DELAY WARNING**
b. EXIT DELAY WARNING
(if programmed)
a.
DISARM SYSTEM OR ALARM WILL OCCUR
is
displayed. Exceeding the delay time without
disarming causes alarm.
b.
ARMED AWAY
or
ARMED MAXIMUM
is displayed
along with
You May Exit Now
* If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
** Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.
*** Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power
only).