FM USER INSTRUCTIONS ENGLISH 71576526 - 03/07
Page 25 of 32 flowserve.com
After setting the last packing, fix the gland on the
packing and screw up the nut by hand.
After this screwing phase, the shaft should turn by
hand as easily as before the setting of the packing.
Dimensions in
mm (in.)
Packing
Pump
type
D1 D2 D3 D4 D5 L1 Lgth
50 FM
24
(0.94)
30
(1.18)
46
(1.81)
70
(2.76)
M10
48
(1.89)
600
(23.62)
8
65 FM
24
(0.94)
30
(1.18)
46
(1.81)
70-
2.76)
M10
48
(1.89)
600
(23.62)
8
6.2.6 Internal coating
If the pump has an internal coating, this coating
must be inspected periodically. Any wear or cracks
of the coating found must be immediately repaired.
Failure to do this may lead to accelerated wear of
the coating during operation and corrosion of the
exposed base metal, depending on the material and
pumped liquid. Special attention must be paid to the
coating edges. Any loss of coating material is
considered to be normal wear and tear on the pump
and is not considered as warranty. Flowserve has
applied the coatings according to the supplier's
instructions but will not be held responsible for
coating wear or cracks that may develop over time.
6.3 Spare parts
6.3.1 Ordering of spares
Flowserve keeps records of all pumps that have been
supplied. When ordering spares the following
information should be quoted:
(1) Pump serial number
(2) Pump size
(3) Part name
(4) Part number
(5) Number of parts required
The pump size and serial number are shown on the
pump nameplate.
To ensure continued satisfactory operation,
replacement parts to the original design specification
should be obtained from Flowserve.
Any change to the original design specification
(modification or use of a non-standard part) will
invalidate the pumps safety certification.
6.3.2 Storage of spares
Spares should be stored in a clean dry area away
from vibration. Inspection and re-treatment of
metallic surfaces (if necessary) with preservative is
recommended at 6 monthly intervals.
6.4 Recommended spares
[1410], [2250], [4610], [4130]
Destroy all the gaskets after dismantling, replace
them when reassembling.
After serving during two years, replace the gland
packing.
6.5 Disassembly
Refer to section 1.6, Safety, and section 6
Maintenance, before dismantling the pump.
Before dismantling the pump for
overhaul, ensure genuine Flowserve replacement
parts are available. Refer to sectional drawings for
part numbers and identification.
REPAIR OF THE PUMP
If the pump presents abnormalities or a
persistent malfunction, contact immediately:
FLOWSERVE
After-sales Service
Tel.: 02 43 40 57 57
(33) 2 43 40 57 57
Fax.: 02 43 40 58 17
(33) 2 43 40 58 17
According to the After-sales Service instructions,
disassembly will be limited to the dismantling of the
pump.