PERFORMANCE SPECIFICATIONS
PRESSURE ADDED - PSI 10 20 40 60 80 100 120 140 160 180 200
Max.
Press.
PSI
Suction
Pipe
Tap
NPT
Disch.
Pipe Tap
NPT
Stainless
Steel Fitted
Powder-
Coated Cast
Iron Fitted
Cast Iron
Fitted
HP Stage Output - Gallons per Minute
PB0508C031 PB0508A031• 1/3 8 9.5 8.7 7.3 5.8 3.5 87
3/4” 3/4”
PB0512S051 PB0512C051 PB0512A051• 1/2 12 9.8 9.2 8.2 7.3 6.3 5.2 3.5 131
PB0516S071 PB0516C071 PB0516A071 3/4 16 9.9 9.5 8.7 8.0 7.3 6.5 5.8 4.8 3.5 175
PB0712S071 PB0712C071 PB0712A071• 3/4 12 14.0 13.4 12.2 10.9 9.5 7.9 6.0 3.6 152
PB1014S101 PB1014C101 PB1014A101 1 14 * * 14.5 13.4 12.3 11.2 9.8 8.3 6.3 3.3 185
PB1016S151 PB1016C151 PB1016A151 1-1/2 16 * * 14.7 13.8 12.9 11.9 10.8 9.7 8.2 6.6 4.3 211
PB1914S201 PB1914C201 PB1914A201 2 14 27.5 27.0 25.7 24.2 22.6 20.8 18.7 16.2 13.0 7.8 190
PB3506S201 PB3506C201 PB3506A201 2 6 41.5 41.1 40.5 34.2 23.3 90
1” 1”
PB2711S201 PB2711C201 PB2711A201 2 11 * * 31.3 29.3 26.8 23.8 19.8 13.0 150
PB3508S301 PB3508C301 PB3508A301 3 8 41.5 41.1 40.9 40.0 34.2 26.4 10.0 120
PB2714S301 PB2714C301 PB2714A301 3 14 * * 32.2 30.6 28.9 27.0 24.8 22.0 18.4 12.2 190
--
PB5504A201 2 4 77.6 71.5
52.5
55
2” 2”
--
PB5506A301 3 6 77.8 74.4
65.0
51.1
31.9
83
--
PB8504A201 2 4 105.8 90.0
47.0
49
--
PB8505A301 3 5 108.8 98.8
60.0
25.0 60
† Example: If PB0508A031 pump is connected to supply line of sufficient capacity, carrying water at 40 PSI, and the output of the pump is held to 7.3 GPM by a
gate valve, the pump will add 40 PSI to line pressure for a total output pressure of 80 PSI.
* Operation of pump in this range may result in reduced pump life and/or motor damage.
To keep pump and seal lubricated, a minimum flow of 1.5 GPM must always be maintained through the pump.
Motor voltage: Single Phase 1/3 - 2 HP - 115/230; 3 HP - 230V 60 Hz.
Three Phase 1/2 - 2 HP - 208-230/460, 50/60Hz.
Three Phase 3 HP - 208-230/460, 60 HZ
For three phase models, use suffix “3” on the model no. Example: PB0512A053
• Handle included with these models only.
Single Phase Motor Data 60HZ Chart C
Single Phase† 60 Hz 3450 RPM Capacitor Start
HP
Motor
Voltage
Factory
Connected
Motor
Voltage
Service Factor Motor
Amps
Locked Rotor Motor
Amps
Code Letter
115V 230V 115V 230V
1/3
1/2
3/4
1
1-1/2
2
3
115/230
115/230
115/230
115/230
115/230
115/230
230
115V
115V
115V
230V
230V
230V
230V
8.6
13.0
14.0
18.0
21.0
25.0
-
4.3
6.5
7.0
9.0
10.5
12.5
13.5
26.0
36.0
52.0
78.0
98.0
116.0
-
13.0
18.0
26.0
39.0
49.0
58.0
53.0
K
K
K
L
J
H
D
Single Phase Motor Data 50HZ
Single Phase† 50 Hz 2850 RPM Capacitor Start
1/2
3/4
1
1-1/2
2
115/230
115/230
115/230
115/230
230
115V
115V
230V
230V
230V
10.0
14.4
16.4
23.6
-
5.0
7.2
8.2
11.8
13.2
48.0
64.0
72.0
104.0
-
24.0
32.0
36.0
52.0
55.0
M
L
K
K
H
†Thermal overload protector - automatic reset