Heatiator I80 Indoor Fireplace User Manual


 
Heatilator • I80 CAN-US • 4013-203 Rev F • 04/08
9
3
3
Framing and Clearances
A. Selecting Fireplace Location
Several options are available to you when choosing a loca-
tion for your replace. This replace may be used as a room
divider, installed along a wall, across a corner or used in an
exterior chase. See Figure 3.1.
51-1/2 in.
1308 mm)
5/8 in. (16 mm)
all configurations
In an exterior chase
or projecting into a
garage
Across a
corner
As a room
divider
Along a wall
A
A
48 in.
(1219 mm)
min.
A
1-1/2 in. (38 mm) min.
distance from sides & back
of fireplace to combustible
materials. 1/2 in. (13 mm)
min. at nailing flanges.
Note:
Note:
In addition to these
framing dimensions,
also reference the
following sections:
• Clearances (Section
3.B.)
• Mantel Projections
(Section 8.C)
• Fireplace Dimensions
(Section 12.A.)
65-5/8 in.
(1667 mm)
46-3/8 in.
(1178 mm)
92-3/4 in. (2356 mm)
28-1/2 in.
(724 mm)
28-1/2 in.
(724 mm)
28-1/2 in. (724 mm)
21-1/2 in.
(546 mm)
24 in.
(610 mm)
min.
24 in.
(610 mm)
min.
24 in.
(610 mm)
min.
Figure 3.1 Fireplace Locations
Fire Risk
Provide adequate clearances.
Around air openings
• To combustibles
For service access.
Locate replace away from traf c areas.
WARNING
Note:
Illustrations and photos re ect typical installations
and are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation/appearance may vary due to
individual design preference.
Hearth & Home Technologies reserves the right to
alter its products.
Locating the replace in a basement, near frequently opened
doors, central heat outlets or returns, or other locations of
considerable air movement can affect the performance and
cause intermittent smoke spillage from the front of the re-
place. Consideration should be given to these factors before
deciding on a location. See Sections 2 and 10.
I80 A
With Outside
Air
in. 59-1/2
mm 1511
Without
Outside Air
in. 51-1/2
mm 1308
¨