27
Termination Cap
Storm Collar
Slope Downward
Turn-down
Drip Edge
Chase
(Chimney)
2 in. (51 mm) Collar
on Chase Top
Caulk
.018 (26 ga) min.
Galvanized
Chase Top
Figure 6.3 Chase Top Construction
2 in. (51 mm) min. collar
6 in. (152mm) min.
2 in. (51 mm) min.
Storm Collar
Flashing Collar
Minimum 1-1/2 in. (38 mm) overlap of cap over pipe
Figure 6.4 Installing a TR11 or TR444 Round Termination Cap
Storm Collar
Flashing Collar
Top of Pipe
14-1/2 in. (368mm) max.
1-1/2 in. (38 mm) min.
overlap
2 in. (51 mm) min.
Figure 6.5 Installing a TR11T or TR442 Round Telescoping Termi-
nation
Cap
Note: To protect against the effect of corrosion on those
parts exposed to the weather, the termination cap can be
painted with a rust-resistant paint.
Fire Risk
The minimum overlap of cap to pipe
MUST be met or chimney may separate
from cap.
Separation allows sparks, heat and embers
to escape.
WARNING
C. Install the Termination Cap
For installations utilizing a TR11T or TR442 Round
Telescoping Termination Cap, the uppermost chimney
section must be below the top of the chase top, but not
more than 14-1/2 in. (368 mm) below the top of the chase
top. Minimum overlap of chimney and termination cap
must be 1-1/2 in. (38 mm). See Figure 6.5.
Install the chimney sections up through the chase
enclosure. When using a TR11 or TR444 Round
Termination Cap, the uppermost top section of pipe must
extend 6 in. (152 mm) above the top of the ashing collar
to allow installation of the storm collar and termination cap.
See Figure 6.4.
B. Chase Top
A metal chase top is required to seal the top of the chase
around the chimney pipe. The top should include a turn-
down and drip edge to prevent water from seeping into the
chase. Provide a 1/8 in. (3 mm) gap around the ue pipe
and slope the top downward away from the penetration. See
Figure 6.3.
All seams must be caulked to prevent leaks.
A chase installation must use a chase top. Chase tops
are available from your Heatilator dealer or may be eld
constructed.
Attach the chase top to the top of the chase.