2 in. (51 mm) min.
4-1/2 in.
(114 mm)
max.
1-1/2 in.
(38 mm) min.
overlap
Cap Standoff
Top of Pipe
Flashing Collar
Figure 6.6 Installing an ST1175 or ST475 Square Termination Cap
For installations utilizing an ST1175 or ST475 Square
Termination Cap the last chimney section must not be
more than 4-1/2 in. (114 mm) below the chase top. See
Figure 6.6.
The last section of pipe
must stop between the
distances given below.
2 in. (51 mm) above top
of the chase.
7 in. (178 mm) below top
of the chase.
{
Top of Pipe
1-1/2 in. (38 mm)
min. overlap
Figure 6.7 Installing a TCT1175 Terra Cotta Cap (available is US
only)
For installations utilizing an TCT1175 Terra Cotta Cap the
last chimney section must be between 7 in. (178 mm) below
the chase top and 2 in. (51 mm) above. See Figure 6.7.
For chase installations you can use a TR11 or TR444
Round Termination Cap, a TR11T or TR442 Round
Telescoping Termination Cap, an ST1175 or ST475 Square
Termination Cap, or a TCT1175 Terra Cotta Termination
Cap.
For installations utilizing a European Copper Series
Termination Cap, See Figure 6.8.
chimney top
2 - 6 in.
(51-152 mm)
2 in. (51 mm)
typical
chase
top
(metal or masonry)
Cap Base
(cap inner flue)
SL pipe
inner flue
screw (8)*
bracket (8)
Figure 6.8 Installing a European Copper Series Termination Cap
(CT11-King shown, available in US only)
Install termination caps following instructions provided
with them.