Heatiator GB4336 Indoor Fireplace User Manual


 
Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06 27
Handle glass with care.
Inspect the gasket to ensure it is
undamaged.
Inspect the glass for cracks, chips or
scratches.
Do NOT strike, slam or scratch glass.
Do NOT operate appliance with glass
assembly removed, cracked, broken or
scratched.
Replace glass assembly as a complete
assembly.
WARNING
H. Hood
The hood is shipped on top of the outer shell of the appli-
ance. Remove the hood from its shipping location. Locate
the four hood retaining clips and slide the hood into them.
The hood must be attached or a fi re hazard may result. See
Figure 12.10.
Figure 12.10 Installing the Hood
G. Glass Doors
I. Air Shutter Setting
• Closed position - natural gas
• Open position - propane
Figure 12.11 Air Shutter
Note: Glass doors are not optional in the Commonwealth
of Massachusetts. They are required.
If you have decided to install optional doors on your appli-
ance, please use them correctly. While operating your appli-
ance, you should either have the doors completely open or
completely closed, but never partially open.
Fire Risk
Combustion Fumes Risk
• Appliances equipped with optional glass
doors must be operated with doors fully
open or fully closed.
Only use glass doors certifi ed for use with
this appliance.
If doors are left partially open, gas and
ames may be drawn out of the appliance
opening.