Measured from top of hood (in inches)
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
5
5-1/2
6-1/4
7
7-3/4
8-1/2
9-1/4
10
10-3/4
11-1/2
12-1/4
13
13-3/4
14-1/2
15-1/4
16
30 in. minimum
to ceiling
1 in. (25 mm) min.
to perpendicular wall
A
3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
B
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
B
13
Finishing
A. Mantel and Wall Projections
Comply with all minimum clear-
ances as specied. Framing closer than the minimums
listed must be constructed entirely of noncombustible
materials (i.e., steel studs, concrete board, etc.) Failure to
comply could cause re.
Figure 13.1 Minimum Vertical and Maximum Horizontal Dimen-
sions
Mantels
Figure 13.2 Mantel Leg or Wall Projections (Acceptable on both
sides of opening)
Mantel Legs or Wall Projections
These surfaces
may be covered
with non-combustible
material.
Non-combustible
sealant.
B. Facing Material
Metal front faces may be covered with non-combustible
materials only.
Facing and/or nishing materials must not interfere with
air ow through louvers, operation of louvers or doors,
or access for service.
Facing and/or nishing materials must never overhang
into the glass opening.
Observe all clearances when applying combustible
materials.
Seal joints between the nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 13.3.
apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specied in this
manual. Overlapping materials could ignite and will inter-
fere with proper operation of doors and louvers.
Figure 13.3 Noncombustible Facing Diagram