Heatiator CB4236IR Indoor Fireplace User Manual


 
Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/0918
0 in.
C
B
A
Note: All pipe clearance
specifications are per vent
manufacturer's installation
instructions.
0 (Clearance to
Standoffs)
30 in.
(762 mm)
clearance to ceiling
1/2 in. (13 mm)
1/2 in.
(13 mm)
Drywall
0 in.
Per Vent
Manufacturer’s
Specifications
Combustible flooring may be installed
next to the front of the appliance.
Combustible Object
36 in.
(914 mm)
A
Rough Opening
(Width)
B
Rough Opening
(Height)
C
Rough Opening
(Depth)
in.
42 38-3/4 23-1/2
mm
1,067 984 597
in.
48 38-3/4 23-1/2
mm
1,219 984 597
CB4236I
CB4842I
Model
Figure 5.2 Clearances to Combustibles
C. Clearances
Maintain specied air space
clearances to appliance and vent pipe:
Insulation and other materials must be secured to
prevent accidental contact.
The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with replace or chimney.
Failure to maintain airspace may cause overheating and
a re.
Note: If the inside of the framed cavity is to be nished,
the framing dimensions must include the nished surface.
Example: If drywall is to be attached to the rear wall, the
depth must be measured from the drywall surface.
Note: The appliance must be raised 1 1/4 in. (32 mm) off oor so
the Harbor System can be used. Adjust framing and vent locations
accordingly.
Install appliance on hard metal or wood surfaces
extending full width and depth.  install directly on
carpeting, vinyl, tile or any combustible material other than
wood.