Heatcraft Refrigeration Products CH-B-01 Humidifier User Manual


 
8
Model KMK
Mullion Reach In Unit Cooler
APPLICATION
The KMK Mullion is ideal for under-counter reach-in
refrigerators. The thin line design allows the unit to be
mounted behind the mullion with sufficient clearance for
tray slides. A down flow fan arrangement is used with air
drawn in at the top and discharged at the bottom. This
design provides superior air circulation and insures
uniform temperature throughout the cabinet.
This versatile design is also adaptable for mounting on the
back wall or ends of a cooler. The method of air circulation
insures minimum box temperature rise when the cabinet
doors are open. Ideal for bottle goods and beverage coolers.
EXCLUSIVE CORROSION-RESISTANT COATING IS STANDARD
The finned coil is protected by a special dip coating that is
baked on. It prevents corrosion of the coil caused by acids
that are present in many food service and storage coolers.
FEATURES
Textured aluminum cabinets.
PVC coated fan guard.
Stainless steel hardware.
Coils have full collar aluminum fins on expanded copper
tubes.
Refrigerant connection knockouts provided on both ends
of unit.
Expansion valve mounts inside the unit.
Motors are thermally protected and permanently
lubricated.
Internal junction box for electrical connection.
Adjustable air deflector included provides different air
patterns. Air can be directed where it is needed.
UL listed for the United States and Canada; UL classified to
NSF standards.
Corrosion-resistant coated coil for optimum protection in
corrosive environments.
DIMENSIONAL DATA
MODEL DIMENSIONS (INCHES)
KMK H L M W X Y Z
13 17
3
/4 16
7
/8 9 15
5
/8 2
3
/4 5
1
/2 6
15
/16
17 19
3
/4 16
7
/8 10 15
5
/8 2
3
/4 6
1
/2 7
15
/16
23 19
3
/4 23
1
/4 10 22 2
5
/16 6
1
/2 7
15
/16
MOTOR DATA APPROX.
MODEL BTUH 115/1/60 208-230/1/60 CONNECTIONS (IN.) SHIPPING
KMK 10
°
F TD CFM QTY
TOTAL FLA TOTAL FLA INLET SUCTION DRAIN WT. (LBS.)
13 1300 180 2 1.6 0.8 1/2FN 3/8OD 5/8OD 19
17 1700 170 2 1.6 0.8 1/2FN 3/8OD 5/8OD 20
23 2300 255 3 2.4 1.2 1/2FN 3/8OD 5/8OD 28
Performance/Electrical Data
KM K 13 A E
Vintage
A = 115/1/60
B = 208-230/1/60
KMK = Mullion
Unit Cooler
K = Coated
Coil
Size
NOMENCLATURE