10
DIMENSIONAL DIAGRAM
Model U
Dual Aire Reach In Unit Cooler
APPLICATION
The U unit cooler is used wherever a small, compact unit is
required. It can be mounted on the ceiling or wall. The model
U unit draws air through the front and discharges it out both
sides to insure proper distribution of cool air and thus maintain
a uniform box temperature.
FEATURES
• Textured aluminum cabinet.
• Full collar aluminum fins on expanded copper tubes.
• Detachable drain pan that is easy to clean.
• Molded 3-prong motor connector to save installation time
and expense.
• Motors are thermally protected and permanently
lubricated.
• Optional coated coil available (Model UK) for optimum
protection in corrosive environments.
• All sizes UL-component recognized and NSF approved.
U (K) 09 0
0 = 115/1/60
1 = 208-230/1/60
U = Dual Aire
Unit Cooler
K = Coated Coil
(Optional)
Size
NOMENCLATURE
MOTOR DATA
CONNECTIONS (In.)
APPROX.
MODEL
BTUH CAPACITY
115/1/60V 208-230/1/60V COIL SHIPPING
U10°TD 15°TD CFM
TOTAL FLA TOTAL FLA
INLET SUCTION WT. (LBS.)
09 850 1275 190 .45 .55
1
/2 FN
3
/8 ID 9
12 1150 1725 250 .45 .55
1
/2 FN
3
/8 ID 10
15 1500 2250 310 1.10 .55
1
/2 FN
3
/8 ID 14
Performance/Electrical Data
PHYSICAL DATA
MODEL DIMENSIONS (In.)
UHWDABC
09 8
1
/2 11
1
/2 8
7
/8 643
1
/2
12 8
1
/2 17
1
/2 8
7
/8 12 4 9
1
/2
15 9
1
/2 17
1
/2 10
7
/8 12 4 9
1
/2