Heatcraft Refrigeration Products CH-B-01 Humidifier User Manual


 
3
APPLICATION
The Model VA unit cooler is a deluxe unit designed for use in
small reach-ins, back bar and under counter refrigerators, and
many other applications where a small, compact unit is
required. The thermal expansion valve mounts inside the unit.
The unit can be mounted from the ceiling or off the back wall
or end walls.
FEATURES
•Textured aluminum cabinet.
Molded Lexan
®
fan guard.
Improved drain pan overlaps coil surface to catch all
condensate.
Stainless steel screws - prevent rust streaks.
Plate-type aluminum fins with full collars on expanded
copper tubes.
Expansion valve mounts inside cabinet.
Model VA
Reach In Unit Cooler
Internal junction box for electrical connection.
Pigtail leads in junction box.
Motors are thermally protected and permanently lubricated.
Optional corrosion-resistant coated coil available (VAK) for
optimum protection in corrosive environments.
UL listed for the United States and Canada; UL classified to
NSF standards.
VA (K) 08 B E
Vintage
A = 115/1/60
B = 208-230/1/60
VA = Reach-In
Unit Cooler
K = Coated Coil
(Optional)
Size
NOMENCLATURE
MODEL DIMENSIONS (INCHES)
VA A B C D E F H J K W
06 4
5
/16 13
1
/4 4
5
/16 —— 3
3
/8 6
7
/8 5
1
/4 8
1
/8 12
1
/2
08 4
5
/16 13
1
/4 4
5
/16 —— 3
3
/8 6
7
/8 5
1
/4 8
1
/8 12
1
/4
12 4
1
/2 18
3
/4 5
5
/16 —— 3
3
/8 84
7
/8 8
1
/8 18
17 5
1
/4 14
3
/4 5
1
/4 92
1
/2 49
3
/4 6
13
/16 10
1
/2 14
DIMENSIONAL DATA
MOTOR DATA CONNECTIONS (INCHES) APPROX.
MODEL BTUH 115/1/60
208-230/1/60
COIL SHIP WT.
VA 10˚F TD CFM QTY
TOTAL FLA TOTAL FLA
INLET SUCTION DRAIN (LBS.)
06 600 135 1 0.8 0.4 1/2FN 3/8ID 1/2OD 9
08 800 130 1 0.8 0.4 1/2FN 3/8ID 1/2OD 9
12 1200 265 1 1.6 0.8 1/2FN 3/8ID 1/2OD 14
17 1700 245 2 1.0 0.5 1/2FN 1/2ID 1/2OD 11
Performance/Electrical Data