7
Model TL
Thin Profile Electric Defrost Reach In Unit Cooler
APPLICATION
The TL low temperature unit cooler has a completely
automatic defrost system. Mounted in the top of a
refrigerator, its extremely compact cabinet makes it possible
to utilize the entire top shelf area for storage. Having a
normal operating range of +15°F to -20°F, this unit is ideally
suited for such applications as commercial freezers, ice cream
boxes, and bakery freezers.
FEATURES
• Electric defrost insures positive heat source.
• Built-in fan delay allows coil to be chilled before returning
to the normal cooling cycle.
• Defrost terminates on coil temperature eliminating
excessive defrost period.
• Defrost termination and fan delay control, terminal block
and junction box are mounted inside the cabinet.
• Textured aluminum cabinet.
• Molded Lexan
®
fan guards - safety approved.
• Knockouts provided on sides for electrical connections -
opening in rear for coil connections.
• Stainless steel screws.
• Motors are thermally protected and permanently lubricated.
• Internal junction box for electrical connection.
• Plate type aluminum fins with full collars - copper tubes.
• Coils are dehydrated and sealed.
• Easy to install and maintain.
• UL listed for the United States and Canada; UL classified to
NSF standards.
BTUH 10˚F TD
MOTOR DATA HEATER DATA
CONNECTIONS (INCHES)
APPROX.
MODEL +20˚F -10˚F 115/1/60 208-230/1/60 115/1/60 208-230/1/60 COIL SHIP WT.
TL SST SST
CFM QTY
TOTALFLA TOTALFLA
WATTS AMPS AMPS INLET
SUCTION
DRAIN (LBS.)
09 1050 900 110 1 0.8 0.4 475 4.1 2.1
1
/2FN
3
/8ID
1
/2OD 14
12 1380 1200 210 2 1.6 0.8 600 5.2 2.6
1
/2FN
3
/8ID
1
/2OD 19
16 1780 1600 210 2 1.6 0.8 700 6.1 3.0
1
/2FN
1
/2ID
1
/2OD 23
21 2400 2100 240 1 1.0 0.5 1100 9.6 4.8
1
/2FN
1
/2ID
1
/2OD 24
28 3200 2800 335 3 ----- 1.2 1430 ----- 5.7
1
/2FN
5
/8ID
1
/2OD 27
*35 4000 3500 420 2 ----- 1.0 1600 ----- 7.0
1
/2FN
5
/8ID
1
/2OD 38
*53 6100 5300 595 3 ----- 1.5 1950 ----- 8.5
1
/2FN
7
/8ID
1
/2OD 53
Performance/Electrical Data
* These models use external equalized expansion valves.
DIMENSIONAL DATA
MODEL DIMENSIONS (INCHES)
TL A B C D E F H J K L M N P W
09 14
5
/8 14
15
/16 13
1
/2 10
1
/2 11
3
/8 4
1
/2 8
7
/8 2
1
/2
15
/16 4
3
/8 --- 1 16
1
/2
12 18
5
/8 14
15
/16 13
1
/2 10
1
/8 10
1
/4 4
1
/2 8
3
/8 9
1
/2
15
/16 4
3
/8 --- 1 20
1
/2
16 22
1
/8 15
15
/16 14
1
/2 11
1
/8 12 4
1
/2 9
3
/8 11
1
/4
15
/16 4
3
/8 --- 1 24
21 22
1
/8 16
1
/2
15
/16 16
1
/2 14
1
/2 18
7
/8 6
3
/4 11
7
/8 17
1
/4
15
/16 4
3
/8 --- 1
1
/2 24
28 29
3
/4 15
15
/16 14
1
/2 13 20
3
/4 6
3
/4 9
3
/4 9
7
/8
15
/16 4
3
/8 --- 1 31
5
/8
35 35
3
/4 16
1
/2 1
5
/16 16
1
/2 14
1
/2 33
1
/4 6
3
/4 11
5
/8 18
3
/8 1
5
/16 65
1
/8 1
1
/2 38
3
/8
53 46
1
/2 16
1
/2 1
1
/8 16
1
/2 14
1
/2 44 6
3
/4 11
5
/8 30
3
/8 1
1
/2 65
1
/8 1
1
/2 49
1
/8
NOMENCLATURE
Vintage
A = 115/1/60
B =
208-230/1/60
TL = Thin
Profile
Electric
Defrost
Size