Heatcraft Refrigeration Products CH-B-01 Humidifier User Manual


 
11
Models BBM/BBL
Back Bar Reach In Unit Cooler
APPLICATION
The BB models are compact, wall-mounted units whose low
height makes them ideal for undercounter reach-in or drawer-
type fixtures. The unit draws air in at the bottom and
discharges out the front. An optional air deflector is included
and can be mounted over the center of the fan to direct air up
and out. The deflector can be field-formed to direct the air
where needed, usually onto drop-in trays of condiments in
salad bar or sandwich preparation fixtures. An S-type
mounting angle is included to position the unit 3/4" off the
wall which gives optimum air circulation and performance.
The BBM (medium temperature) model is designed for 35° to
40° F. fixture temperature with off-cycle defrost. The unit is
designed to operate at 10° to 17° TD and 16 hours per day
compressor run time.
The BBL (low temperature) model is designed for 0° to -10° F
fixture temperature, and has automatic electric defrost. The
unit is designed to operate at 8° to 15° TD with 18 hours per
day compressor runtime. The BBL has an incoloy sheath
heater embedded in the bottom fin surface for efficient and
fast defrosting. A drain pan heater is included to insure
complete condensate drainage. A disc-type sealed defrost
termination/fan delay control is mounted and wired. Field
connectors are located at the terminal board.
FEATURES
Molded Lexan
®
fan blades and guards.
Coils have copper tubes with aluminum fins, mechanically-
bonded for efficient heat transfer. The coils are dehydrated
and sealed.
Textured aluminum cabinet.
Knockouts are conveniently located for refrigerant lines.
Screws are hardened, stainless steel with a bright zinc
plating.
Expansion valve mounts inside the cabinet and connections
are sweat-type.
Motors are thermally protected and permanently lubricated.
Master units include the basic unit plus factory mounted
Sporlan FV1/5C, R-22, 1/4” x 1/2” sweat expansion valve,
Sporlan E3S, 1/4” x 1/4” sweat solenoid, and Ranco A-30
temperature control. Also right-hand piping extended 8" -
12" outside the housing, sealed and pressurized to 20 - 30
PSI. A 1/4” O.D. liquid feed to slave is included.
Slave units include the basic unit plus factory mounted
Sporlan FV1/5C, R-22, 1/4” x 1/2” sweat expansion valve
with left-hand piping extended 8" - 12" outside the housing,
sealed and pressurized to 20 - 30 PSI.
Performance/Electrical Data
MOTOR DATA DEFROST HEATERS
MODEL BTUH 115/60/1 208-230/60/1 115/60/1
208-230/60/1
BB 10
°
F TD CFM QTY HP
TOTAL FLA TOTAL FLA
WATTS AMPS AMPS
L10 1,000 90 1 1/150 0.8 0.4 275 2.7 1.4
M11 1,100 90 1 1/150 0.8 0.4 --- --- ---
L15 1,500 180 2 1/150 1.6 0.8 350 3.5 1.7
M16 1,600 180 2 1/150 1.6 0.8 --- --- ---
APPROX.
MODEL DIMENSIONS (INCHES) SHIPPING
BB W A B C D E F WT.
(LBS.)
L10 19
3
/
4
19
1
/
8
18 17
1
/
2
7
1
/
16
---- 16
5
/
8
17
M11 19
3
/
4
19
1
/
8
18 17
1
/
2
7
1
/
16
---- 16
5
/
8
16
L15 26
1
/
4
25
5
/
8
24
1
/
2
24 4
13
/
16
8
5
/
8
23
1
/
8
20
M16 26
1
/
4
25
5
/
8
24
1
/
2
24 4
13
/
16
8
5
/
8
23
1
/
8
19
Dimensional Data
TYPICAL
SECTION
OF SANDWICH
STATION
MODEL BBM
BB L S 10 A A
Revision
A = 115/1/60
B = 208-230/1/60
Size
BB = Back Bar
Unit Cooler
L = Low Temp Unit
M = Med. Temp Unit
Blank = Standard Unit
S = Slave Unit
M = Master Unit
NOMENCLATURE