Finishing Instructions
It is important to follow the framing and nishing
instructions to ensure proper placement of replace into
the surrounding framing/ nishing materials.
Wall sheathing materials 1/2 in. thick are speci ed in
this installation manual to properly align with the factory-
installed non combustible material
A. Framing and Finishing Instructions
WARNING! Risk of Fire! DO NOT, under any
circumstances, remove the factory-installed non-
combustible board or cover it with any combustible
material, such as:
Drywall (gypsum board)
• Plywood
Or other materials that do not meet the ASTM E
136 Non-combustibility standard. See speci cation
below
Failure to comply with these instructions may cause a
re or cause the appliance to overheat.
Non-Combustible Materials Speci cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
Setting the Fireplace into the Framing
Unlike many traditional, single-sided Heat & Glo replaces,
this replace is recessed into surround framing. The left
and right nailing tabs were designed for the SLR model
as a means to ensure the replace is recessed to the
correct location within the framing materials.
1. Bend three nailing tabs away from replace 180
degrees on both left and right nailing tabs. Do not
adjust the column standoffs. See Figure 13.1 and
Figure 13.2.
2. Screw each nailing tab to the adjoining framing
material. Ensure that the 1” air space clearance is
maintained on the sides of the replace. See Figure
13.3.
Figure 13.1 Nailing Tabs
Shipping Position
Figure 13.2 Nailing Tabs
Installation Position
Factory-Installed
Non-Combustible
Board
Factory-Installed
Non-Combustible
Board
Top Flange Top Flange
DO NOT ADJUST
NAILING TABS
Figure 13.3 Front Side Finishing Detail
FRAMING
1.00 in.
1/2 in. BUILDING MATERIAL
1-9/16 in.
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as speci ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause re.