Heat & Glo LifeStyle SLR (COSMO) Indoor Fireplace User Manual


 
Heat & Glo • SLR • 2143-900 Rev. B • 7/08 25
H
2
H
1
V
2
V
1
Top Vent - Horizontal Termination
Venting with 3 elbows
Note: Use SLP Series
components only.
1. Top Vent - Horizontal Termination - (continued)
Figure 7.6
SLR
V
1
Minimum H
1
+ H
2
Maximum V
2
V
1
+ V
2
Minimum
90° Elbow 6 ft. 1.8 m * *
1 ft. 305 mm 10 ft. 3.0 m * *
2 ft. 610 mm 12 ft. 3.7 m * *
3 ft. 914 mm 14 ft. 4.3 m * *
H
1
+ H
2
MAX. =14 ft. (4.3 m)
V
1
+ V
2
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
*No speci c restrictions on this value EXCEPT V
1
+ V
2
+ H cannot exceed 40 ft. (12.2 m)
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 7.3).
Note: The SLP-HRC-SS and
SLP-HRC-ZC-SS termination
caps are not approved for use
with propane (LP) fuel.