Heat & Glo LifeStyle CRESCENT II Indoor Fireplace User Manual


 
Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09 29
Figure 10.1 Intelli re Pilot Ignition (IPI) Wiring Diagram - Standard Method Note: Appliance will not operate unless properly grounded.
CAUTION
Wire terminal latch can become
damaged if excessive force is
used when releasing wire. Please
use caution in pressing retainer.
IGNITION
MODULE
3 VAC
INTERMITTENT
PILOT IGNITOR
VALVE
ORG
WHT
ORG
GRN
SWITCH
BACK OF
SWITCH
CIRCUIT BOARD
12VDC
LIGHT SOCKETS
SOLENOID (NG ONLY)
J-BOX
BLACK
GREEN
RED
YELLOW
WHITE
BLACK
BROWN
BROWN
MADE INMADE IN
CANADACANADA
50-025302-D50-025302-D
++
P2P2
HIHI
12V12V
COMCOM
C1C1
C2C2
R1R1
P1P1
REMREM
REMREM
D1D1
J1J1
D2D2
C2C2
K3K3
K2K2
R4R4
K1K1
R1R1
D3D3
C1C1
PRESS. SWPRESS. SW
T16T16
T15T15
LINE NEU
SOLENOID
T14
T13
T12
T11
T10
T9
1
C
3
2
EMBER LIGHTS
HI/LOW
T14
T13
T12
T11
T10
T9
1
C
OFF/ON
3
2
EMBER
T6
T5
T6
T5
IPI
T2 T1T2 T1
TRANSFORMER
3 VAC
PLUG IN
J-BOX
BLACK WIRE CAN
BE PLUGGED INTO
ANY OF #1 - #5
LOCATIONS
ON THE HOT SIDE
WHITE WIRE CAN BE
PLUGGED INTO ANY
OF #1 - #5 LOCATIONS
ON THE NEUTRAL SIDE
PLUG
IN
J-BOX
GROUND
TO FIREPLACE
CHASSIS