Heat & Glo LifeStyle CERONA-36 Gas Heater User Manual


 
Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. A • 6/06
31
A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the junction
box for proper operation of the appliance. This appliance
uses an Intellifire ignition system.
Electrical Information
10
NOTE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA 70-
latest edition or the Canadian Electric Code, CSA C221.1.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
Incorrect wiring will damage millivolt valves.
Incorrect wiring will override IPI safety
lockout and may cause explosion.
Optional Accessories Requirements
Wiring for optional accessories should be done now to avoid
reconstruction.
CAUTION
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous op-
eration. Verify proper operation after servicing.
Shock hazard.
Replace damaged wire with type 105
O
C
rated wire.
Wire must have high temperature insulation.
WARNING
C. Intellifire Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 10.1.
This appliance is equipped with an Intellifire control valve
which operates on a 3 volt system. This appliance is
supplied with a battery pack which requires two D cell
batteries (not included). Batteries cannot be placed in the
battery pack while using the 3 volt AC transformer.
Conversely, the transformer must be unplugged if the battery
pack is used.
CAUTION
Battery polarity must be correct or module damage
will occur.
This appliance includes the WSK300-HNG wall control.
It requires the installation of a wall switch, to be con-
nected to this appliance. Please reference the WSK300-
HNG instructions (2101-915) for specific installation and
operating instructions.
Use the wire provided with this product to connect the
wall switch with the receiver control, as outlined in the
instructions for the WSK300-HNG control.
Keep wire lengths short as possible by removing any
excess wire length.
Low voltage and 110 VAC voltage cannot be shared within
the same wall box.