Heat & Glo LifeStyle CERONA-36 Gas Heater User Manual


 
Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. A • 6/06
17
Cerona-36 ONLY >
Cerona-36 ONLY >
2. Top Vent - Vertical Termination - (continued)
Three Elbows
V
1
+ V
2
Minimum H
1
+ H
2
Maximum
0.5 ft 152 mm 3 ft 914 mm
1 ft 305 mm 4 ft 1.2 m
2 ft 610 mm 7 ft 2.1 m
3 ft 914 mm 10 ft 3.0 m
4 ft 1.2 m 13 ft 4.0 m
5 ft 1.5 m 16 ft 4.9 m
6 ft 1.8 m 19 ft 5.8 m
7 ft 2.1 m 22 ft 6.7 m
H
1
+ H
2
= 22 ft (6.7 m) Max.
V
1
+ V
2
+ H
1
+ H
2
= 62 ft (18.9 m) Max.
Figure 5.8
Figure 5.7
Two Elbows
V
1
+ V
2
Minimum H
1
Maximum
0.5 ft 152 mm 2 ft 610 mm
1 ft 305 mm 2 ft 610 mm
2 ft 610 mm 5 ft 1.5 m
3 ft 914 mm 8 ft 2.4 m
4 ft 1.2 m 11 ft 3.4 m
5 ft 1.5 m 14 ft 4.3 m
6 ft 1.8 m 17 ft 5.2 m
7 ft 2.1 m 20 ft 6.1 m
8 ft 2.4 m 23 ft 7.0 m
H
1
= 23 ft (7.0 m) Max.
V
1
+ V
2
+ H
1
= 63 ft (19.2 m) Max.
V
1
H
1
V
2
H1
V
2
H2
V
1
INSTALLED
HORIZONTALLY
NOTE: Must have a minimum
vertical vent before attaching a
90
o
elbow to the unit. See chart.
Minimal Vertical Vent
Model ft. mm
Cerona-36
0.5 152
Cerona-42
1305
NOTE: Must have a minimum
vertical vent before attaching a
90
o
elbow to the unit. See chart.
Minimal Vertical Vent
Model ft. mm
Cerona-36
0.5 152
Cerona-42
1305