B. Vent Components Diagrams (continued)
DVP-TRAP1
DVP-TRAP2
DVP-TRAPK1
DVP-TRAPK2
DVP-TH
DVP-VTI
DVP-TRAP
Horizontal Termination Cap
15-1/8 in.
(384 mm)
12 in.
(305 mm)
8 in.
(203 mm)
Max
Effective
Length
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the
existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B
will be required.
Heat
Shield
Figure 16.3 DVP vent components
EFFECTIVE LENGTH
Term Cap Minimum Maximum
Trap1 4-1/8 in. (105 mm) 5-5/8 in. (143 mm)
Trap2 6-3/4 in. (171 mm) 10-5/8 in. (270 mm)
DVP-TRAPFL
Flashing