CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Shock hazard.
Replace damaged wire with type 105
O
C
rated wire.
Wire must have high temperature insulation.
WARNING
IGNITION
MODULE
(3V)
VALVE
LOW VOLTAGE
PLUG-IN
3V TRANSFORMER
NEUTRAL HOT
GROUND
FLAME SPARKER/
SENSOR
REMOTE
CONTROL
SEE NOTE 1
VALVE
TRANSFORMER
3 VAC
ORG
WHT
ORG
GRN
ON/OFF
WALL SWITCH
BRN
BRN
BLK
RED
THERMOSTAT
WIRE ASSEMBLY
2045-045
REMOTE JUMPER
WIRE
PLUG IN
IGNITION MODULE 3 VAC
INTERMITTENT PILOT IGNITOR
BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE HOT SIDE
WHITE WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE NEUTRAL SIDE
GROUND TO
FIREPLACE
CHASSIS
LOW VOLTAGE
SEE NOTE 1.
NOTE 1: IGNITION MODULE, VALVE, PILOT AND WALL SWITCH OPERATE ON 3 VOLTS.
120 VAC IS REQUIRED AT JUNCTION BOX UNLESS EQUIPPED WITH BATTERY BACK-UP.
Figure 10.1 Intelli re Pilot Ignition (IPI) Wiring Diagram