Heat & Glo LifeStyle 36DV Indoor Fireplace User Manual


 
Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/0834
Figure 11.4. Non-combustible Finishing Material
Requirements
FRAMING
STANDOFF
COMBUSTIBLE OK
7-1/2 in. MIN.
NON-COMBUSTIBLE MATERIAL
12 IN.
43 IN.
54 IN.
FINISH WALL
NON-COMBUSTIBLE
HIGH TEMPERATURE (300º F / 149º C MIN.)
TOP SEAL JOINT
FINISHING MATERIAL
(TO TOP OF METAL
PANELS)
The nishing material must NEVER pass the 1/2 inch
metal edge around the opening and overhang into the
glass opening.
Fire Risk.
Finishing materials must not interfere with:
Operation of louvers or doors.
Access for service.
• Use the two metal panels shipped with replace.
• Unscrew the four screws holding two panels together.
Slide the two tapered tabs on bottom of each panel into
slots of top surround.
• Secure panels with sheetmetal screws previously
removed from panels.
The metal panels will cover the width of appliance and
height of appliance to header board.
The entire face of the appliance is covered with non-com-
bustible nishing material, such as brick, stone or tile (see
Figures 11.3 and 11.4).
WARNING
Finishing Requirements
Note: Optional rescreen sits out 1-1/2 inches from the face
of the appliance. When using thin nishing material, you
may want to use thicker non-combustible backer board to
bring the nishing material ush with the rescreen. This
is not required.
Fire Risk.
Finish all edges and fronts to clearances and
speci cations listed in manual.
Finishing material must NEVER pass the 1/2 inch metal
edge around opening and overhang into glass opening.
• Only non-combustible material (using 300º F. Minimum
adhesive, if needed) can be applied as facing to replace
surround in rst 4 inches from opening sides and 6 inches
above the opening.
• Install combustible materials only up to specified
clearances on top, front and side edges.
Seal joints between the nished wall and appliance top
and sides using only a 300º F minimum sealant.
WARNING