Heat & Glo LifeStyle 36DV Indoor Fireplace User Manual


 
Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08 15
2. Top Vent - Vertical Termination
No Elbow
Figure 5.6
V
1
V
1
= 40 ft. Max. (12.2 m)
FLUE
RESTRICTOR
Flue Restrictor Instructions
1. The ue restrictor (Figure 5.7) is located behind the right
side panel. Use the restrictor if the vertical vent run is
over 20 feet and has NO elbows.
Figure 5.8 Flue Restrictor
Figure 5.7
Note: On vertical venting con gura-
tions install the ue restrictor (located
behind the right side panel) per the
following ue restrictor instructions.
FLUE RESTRICTOR
2. The restrictor sits inside the 5” diameter collar in the
bead area. Using a needle-nose pliers, insert the tips
of the pliers into the two holes in the restrictor plate.
Squeeze the pliers to ex the plate. The edges of the
plate will need to overlap each other. Insert the plate into
the 5” collar from inside the rebox. Release the pliers,
the plate will expand into the bead (groove) inside the
collar. Make sure the plate is fully in the groove so the
restrictor cannot fall out (see Figure 5.8).
3”
DIAMETER