Heat & Glo LifeStyle 36DV Indoor Fireplace User Manual


 
Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/0814
Figure 5.5
1. Top Vent - Horizontal Termination - (continued)
Three Elbows
V
1
+ V
2
Minimum H Maximum
1-1/2 ft. 457 mm 1-1/2 ft. 457 mm
2 ft. 610 mm 2 ft. 610 mm
2-1/2 ft. 762 mm 5 ft. 1524
3-1/2 ft. 1067 mm 8 ft. 2438
4-1/2 ft. 1372 mm 11 ft. 3353
V
1
+ V
2
+ H
1
+ H
2
= 63 ft. (19.2 m) Maximum
H
1
+ H
2
= 23 ft. (7.1 m) Maximum
H
2
H
1
V
2
V
1
Note: Must have a 12 inches
minimum vertical vent before
attaching any elbow to the unit.