Heat & Glo LifeStyle 2137-900 Indoor Fireplace User Manual


 
Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12
32
Figure 11.1 Noncombustible Facing Diagram
Fire Risk.
Finish all edges and fronts to clearances and
speci cations listed in manual.
• Black metal appliance front may be covered with
noncombustible material only.
Do NOT overlap combustible materials onto appliance
front.
Install combustible materials up to speci ed clearances
on top, front and side.
Seal joints between the nished wall and appliance top
and sides using only a 300ºF minimum sealant.
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
Modifying or covering grilles could cause
temperature rise and re hazard.
Finishing materials must not interfere with:
• Air ow through grilles or louvers.
Operation of louvers or doors.
Access for service.
0 in.
0 in.
0 in.
SEALANT MATERIAL
NON-COMBUSTIBLE ZONE
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
8 in.
31-11/16 in.
B. Mantel Projections
A Studio front is required for all installs. No mantels are
allowed when using Studio fronts.
Risk of Fire
• Non-combustible clearances MUST be
maintained.
• Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the
non-combustible zone.
• See Section 11 for proper clearances.
• See Section 1 for combustible/non-combustible
de nitions.
WARNING
WARNING
WARNING
11
11
Finishing
A. Facing Material