Heat Controller 7602-443 Thermostat User Manual


 
6
Installation Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Heat Controller, Inc.
2.2.2 AUXILIARY HEAT
Adjust the Auxiliary Heat options using the up/down arrow
buttons. Press the center button to save changes.
• Electric (default) – for control of a system with
electric auxiliary heat
• Multi-Fuel – for control of a system with furnace
for auxiliary heat
• No Auxiliary Heat – for control of a system with no
auxiliary heat
2.2.2.1 AUXILIARY HEAT CONFIGURATION
Select Electric Auxiliary Heat mode
Auxiliary Heat to Supplement Pump
Auxiliary Heat for Emergency Heat Only
2.2 THERMOSTAT CONFIGURATION
Upon initial power up, the communicating thermostat will
prompt the installer for the thermostat con guration settings.
2.2.1 STAGING
Adjust the staging option using the up/down arrow buttons.
Press the center button to save changes.
• Single Stage – for control of a single stage
compressor applications
• Multi-Stage (default) – for control of multi-
stage compressor applications
2.0 Installer Menu Settings
2.1 INSTALLER MENU SETTINGS ACCESS
The Installer Settings can be accessed at any time from the
Main Operating screen by holding the up/down arrows simul-
taneously for 5 seconds while the thermostat is in OFF Mode.
Thermostat Con guration
System Con guration
Air ow Selection
Option Selection
Unit Con guration
Valve Con guration
Accessory Con guration
Air Filter
Humidi er
UV Lamp
Air Cleaner
Input Dealer Information
Humidity Con guration
Temperature Algorithm
Demand Reduction Con guration
Service Mode
Manual Operation
Control Diagnostics
Dipswitch Con guration
Fault History
Clear Fault History
Restore Defaults
Installer Menu Settings Overview
INSTALLER SETTINGS
THERMOSTAT CONFIG
SYSTEM CONFIG
ACCESSORY CONFIG
INPUT DEALER INFO
HUMIDITY CONFIG
TEMPERATURE CONTROL
DEMAND REDUCTION CNFG
SERVICE MODE
RESTORY DEFAULTS
DXM2 1.0
ATC32U01 C 2.1
SELECT OPTION
PREVIOUS
THERMOSTAT
CONFIGURATION
SINGLE STAGE
MULTI STAGE
SELECT OPTION
PREVIOUS SAVE
THERMOSTAT
CONFIGURATION
ELECTRIC
MULTI FUEL
NO AUXILIARY HEAT
SELECT OPTION
PREVIOUS SAVE
THERMOSTAT
CONFIGURATION
AUXILIARY HEAT TO
SUPPLEMENT HEAT PUMP
AUXILIARY HEAT FOR
EMERGENCY HEAT ONLY
SELECT OPTION
PREVIOUS SAVE