Hearth and Home Technologies ST-550TM-IPI Indoor Fireplace User Manual


 
Heat & Glo • ST-550TM-IPI • 2142-900 Rev. B • 11/0852
H. Air Shutter Setting
This appliance has an adjustable air shutter (which con-
trols the primary air) factory set for the minimum vertical
vent run. If your installation has more than the minimum
required vertical vent length, adjustment of the air shutter
may be necessary to obtain optimal ame appearance.
This should be adjusted by a quali ed installer at the
time of installation.
Figure 14.5 Fixed Glass Assembly
F. Fixed Glass Assembly
Removing Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
DO NOT strike, slam or scratch glass.
DO NOT operate replace with glass removed, cracked,
broken or scratched.
Replace as a complete assembly.
Air Shutter Settings
G. Install Trim Kits and Surrounds
• Install optional trim kits and/or surrounds using the
instructions included with the accessory.
Use non-combustible materials to cover the gap between
the sheet rock and the appliance (if desired).
Removing Fixed Glass Assembly
Pull the two glass assembly latches out of the groove on
the glass frame (see Figure 14.5).
• Remove glass door from the bracket on the top of the
rebox.
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance.
• Pull out and latch the two glass assembly latches into
the groove on the glass frame.
• Make sure both sides are replaced properly.
NG LP
Burner Full Closed 1/8 in.
GLASS
ASSEMBLY
LATCHES
(BOTH BOTTOM
AND TOP)