Hearth and Home Technologies ST-550TM-IPI Indoor Fireplace User Manual


 
Heat & Glo • ST-550TM-IPI • 2142-900 Rev. B • 11/08 27
Figure 7.5
Two Elbows
V
1
Minimum H
1
+ H
2
Maximum
1 ft.** 305 mm 1 ft. 305 mm
2 ft.** 610 mm 2 ft. 610 mm
3 ft.** 915 mm 4 ft. 1.2 m
4 ft. 1.2 m 6 ft. 1.8 m
5 ft. 1.5 m 14 ft. 4.3 m
H + H
1
Max. =14 ft. (4.3 m)
V + H + H
1
Max. = 40 ft. (12.2 m)
See Warning Below**
1. Top Vent - Horizontal Termination - (continued)
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 7.3).
WARNING**
Fire Risk.
• When using SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps on top vented replaces, a two
foot minimum vertical vent section is required before
installing rst elbow.
When using DVP-TB1 termination cap on top vented
replaces, a three foot minimum vertical vent section
is required before installing rst elbow.
When using any other cap, a section of vertical pipe (12 inches
minimum) MUST be installed prior to attaching a 90° elbow.