Hearth and Home Technologies ST-550TM-IPI Indoor Fireplace User Manual


 
Heat & Glo • ST-550TM-IPI • 2142-900 Rev. B • 11/0830
Figure 7.9
Two Elbows
Three Elbows
Figure 7.10
V
1
Minimum H Maximum V
2
V
1
+ V
2
Min.
1 ft. 305 mm 2 ft. 610 mm * *
2 ft. 610 mm 3 ft. 914 mm * *
3 ft. 915 mm 5 ft. 1.5 m * *
4 ft. 1.2 m 7 ft. 2.1 m * *
5 ft. 1.5 m 15 ft. 4.6 m * *
H Max. =15 ft. (4.6 m)
V
1
+ V
2
+ H Max. = 40 ft. (12.2 m)
* No speci c restrictions on this value EXCEPT V
1
+ V
2
+ H cannot exceed 40 ft. (12.2 m)
V
1
Minimum H Maximum V
2
V
1
+ V
2
Min.
1 ft. 305 mm 1 ft. 305 mm * *
2 ft. 610 mm 2 ft. 610 mm * *
3 ft. 915 mm 4 ft. 1.2 m * *
4 ft. 1.2 m 6 ft. 1.8 m * *
5 ft. 1.5 m 14 ft. 4.3 m * *
H MAX. =14 ft. (4.6 m)
V
1
+ V
2
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
* No speci c restrictions on this value EXCEPT V
1
+ V
2
+ H
1
+ H
2
cannot exceed 40 ft. (12.2 m)
H
1
V
2
V
1
INSTALLED
HORIZONTALLY
H
1
H
2
V
2
V
1
Note: A section of vertical pipe (12 inches minimum)
MUST be installed prior to attaching a 90° elbow.
Note: A section of vertical pipe (12 inches minimum)
MUST be installed prior to attaching a 90° elbow.