Hearth and Home Technologies ST-550TM-IPI Indoor Fireplace User Manual


 
Heat & Glo • ST-550TM-IPI • 2142-900 Rev. B • 11/0814
Porcelain Firebox Panel Cleaning
Frequency: Seasonally
By: Homeowner
Tools Needed: Protective gloves, glass cleaner, drop
cloth and a stable work surface.
CAUTION! Handle xed glass assembly with care.
Glass is breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
DO NOT clean glass while it is hot
Prepare a work area large enough to accommodate xed
glass assembly and door frame by placing a drop cloth
on a at, stable surface.
Note: Fixed glass assembly and gasketing may have res-
idue that can stain carpeting or oor surfaces.
Remove door or decorative front from replace and set
aside on work surface.
• See Section 14.F for instructions to remove xed glass
assembly.
Clean porcelain panels with a non-abrasive commercially
available cleaner.
• Carefully set xed glass assembly in place on replace.
Hold glass in place with one hand and secure glass
latches with the other hand.
• Reinstall door or decorative front.
Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds). See
Section 6.
• Inspect for corrosion or separation.
• Verify weather stripping, sealing and ashing remains
intact.
Inspect draft shield to verify it is not damaged or missing.
B. Maintenance Tasks-Quali ed Service
Technician
The following tasks must be performed by a quali ed ser-
vice technician.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect xed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
• Con rm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Firebox
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
• Replace replace if rebox has been perforated.
Control Compartment and Firebox Top
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths.
Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
• Remove all foreign objects.
• Verify unobstructed air circulation.