Hearth and Home Technologies SL-550TR-IPI-E Indoor Fireplace User Manual


 
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. L • 11/0858
B. Facing Material
Metal front faces may be covered with non-combustible
materials only.
• Facing and/or nishing materials must not interfere with
air ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 13.6.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as speci ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
Figure 13.6 Facing Materials
Models: SL-550TR-E, SL-750TR-E
SL-550TR-IPI-E, SL-750TR-IPI-E
0 INCH
(0 mm)
1 INCH
(25 mm)
FINISH WALL MATERIAL
MAY BE COMBUSTIBLE
TOP AND SIDES
TOP SEAL
JOINT
SIDE SEAL
JOINT
NON-COMBUSTIBLE STRIP
SHIPPED WITH UNIT
Figure 13.7 Facing Materials
Models: SL-950TR-E, SL-950TR-IPI-E
HIGH TEMPERATURE (300 ºF/ 149 ºC MIN.)
TOP AND SIDE SEAL JOINT
BOTTOM 1 INCH (SHADED AREA)
MAY BE COVERED WITH COMBUSTIBLE
OR NON-COMBUTIBLE MATERIAL
1 IN.
1 IN.
0 IN.
0 IN.
0 IN.
FACING MATERIAL UP TO 1/2 IN. THICK
MAY BE COMBUSTIBLE - TOP AND SIDES