Hearth and Home Technologies SL-550TR-IPI-E Indoor Fireplace User Manual


 
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. L • 11/0842
B. Rear Vent
NOTICE: Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.
NOTICE: Once the seal cap has been removed it CANNOT
be reattached.
Figure 9.8 Fold the tabs toward the center of the re plug
(90°) and remove the insulation gasket.
Figure 9.9 Cut the metal retaining band and fold the
sides out.
Figure 9.10 Fold the center parts of the retaining band
out and use to remove the seal cap.
Figure 9.11 Discard the seal cap, remove and discard
the insulation basket. Note: Once the vent cap has been
removed it CANNOT be reattached.
Figure 9.12 Attach the rst vent section (it will snap into
place). Slide the insulation gasket onto the vent section,
up against the appliance and over the tabs. Use two self-
tapping screws to secure gasket to outer wrap.
Figure 9.7 To attach the rst section of vent pipe, make
sure to use the berglass gasket to seal between the rst
vent component and the outer replace wrap. Use 2 self
tapping screws to secure the gasket to the outer wrap.
Note: Once the vent cap has been removed, it cannot be
reattached.
2 SCREWS