Hearth and Home Technologies SL-350TRS-IPI Indoor Fireplace User Manual


 
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 31
Assembling DVP-12A Slip Sections
The outer ue of the slip section should slide over the outer
ue of the pipe section and into (inner ue) the last pipe
section (see Figure 8.6).
Slide together to the desired length, making sure that a
1-1/2 inch outer ue overlap is maintained between the
pipe section and slip section.
Assembling Minimum Installations (MI) Sections
MI sections are non-unitized so that they can be cut to a
certain length. Cut these sections to length from the non-
expanded end (see Figure 8.5).
They can then be attached by rst connecting the expanded
end of the MI inner ue with the inner pipe from the adjacent
pipe section and securing with three screws. The expanded
portion of the MI inner ue must overlap completely with
the unexpanded end of the adjacent pipe section.
The outer ue can then be inserted into the adjacent outer
ue expanded end and attached to the next pipe section
with three screws. The other end of the MI pipe section can
then be attached by tting another pipe section to it and
snapping it together, as normal.
Figure 8.6 Slip Section Pilot Holes
Figure 8.7 Screws into Slip Section
Figure 8.5
Cut from this end
Cut from this end
(inner)
(outer)
Pilot hole
Figure 8.4 Seams
Note: Make sure that the seams are not aligned to
prevent unintentional disconnection.
INCORRECT
CORRECT
The pipe and slip section need to be secured by driving
two screws through the overlapping portions of the outer
ues using the pilot holes (see Figure 8.7).
This will secure the slip section to the desired length and
prevent it from separating. The slip section can then be
attached to the next pipe section.
If the slip section is too long, the inner and outer ues of
the slip section can be cut to the desired length.
Note: When installing a vent system with an HRC termination
cap, all pipe system joints shall be sealed using a high-
temperature silicone sealant.
• Apply a bead of silicone sealant inside the female outer
pipe joint prior to joining sections.
• Only outer pipes are sealed, sealing the inner ue is not
required. All unit collar, pipe, slip section, elbow and cap
outer ues shall be sealed in this manner.