Hearth and Home Technologies Everest Indoor Fireplace User Manual


 
Heat & Glo • Everest • 750-900 Rev. o • 10/08 22
!
Step 4. Positioning, Leveling, and
Securing the Fireplace
The diagram below shows how to properly position, level,
and secure the replace.
!
!
Figure 20. Proper Positioning, Leveling, and Securing
of a Fireplace
Figure 21. Intermittent Pilot Ignition
NAILING TABS
(BOTH SIDES)
Step 5. The Gas Control Systems
1. Place the replace into position.
2. Level the replace from side to side and from front to
back.
3. Shim the replace with non-combustible material, such
as sheet metal, as necessary.
4. Secure the replace to the framing by nailing or screw-
ing.
Intermittent Pilot Ignition (IPI) System
The gas control system used with this model is Intermittent
Pilot Ignition (IPI). This system includes a 3V control valve,
electronic module, and intermittent pilot.
WARNING: DIRECT VENT PROPANE MODELS
WITH IPI CONTROL SYSTEMS CANNOT BE
USED IN CANADA.
WARNING: CONTINUOUS 110-120 VAC SER-
VICE MUST BE WIRED TO THE FIREPLACE
JUNCTION BOX.
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.