Figure 10. Vertical Baf e
1. Attach the First Vent Component to the
Starting Collars
To attach the rst vent component to the starting collars
of the replace:
• Make sure that the replace gasket supplied with the
replace seals between the rst component and the outer
replace wrap.
• Refer to Cinch Pipe and Termination Cap installation
instructions.
B. Installing Vent Components
If your vertical vent component is over 10 feet, you may
want to install the included vertical baf e to improve ame
appearance. Vertical baf e is located in the bag containing
the instruction manual. Center the vertical baf e on the ve
inch vent being used, and with self tapping screws secure
the baf e to the inside of the rebox (see Figure 10).
With vent runs of 30 feet or more without elbows, an
additional baf e (SRV750-152) is to be used with the
supplied baf e. This is a service part and is to be purchased
separately.
VERTICAL
BAFFLE
5” EXHAUST
PIPE
2. Assembling Vent Sections
Refer to Cinch Pipe and Termination Cap installation in-
structions.
!
WARNING: ENSURE THAT THE FIBERGLASS
GASKET SUPPLIED WITH THE FIREPLACE
SEALS BETWEEN THE FIRST VENT COMPO-
NENT AND THE OUTER FIREPLACE WRAP.
If the installation is for a termination cap attached directly
to the replace, skip to the sections, Install Firestops and
Vent Termination.