Hearth and Home Technologies Cyclone-Cust Indoor Fireplace User Manual


 
Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/0840
DVP-TRAP SERIES
Horizontal Termination Cap
15-1/8 in.
14 in.
8 in.
Max
Effective
Length
Heat Shield
DVP-TRAP1
DVP-TRAPK1
Horizontal Termination Cap Kit
DVP-TRAP1
Horizontal Termination Cap Kit
DVP-TRAPK2
Horizontal Termination Cap Kit
DVP-TRAP2
Horizontal Termination Cap Kit
(Shown with optional extended heat shield)
DVP90ST
Heat Shield
DVP-TRAP1
Wall Shield Firestop
Wall Shield Firestop
Wall Shield Firestop
Wall Shield Firestop
HSM
Heat Shield
DVP-TRAP2
Heat Shield
DVP-TRAP2
DVP90ST
HSM
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the
existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B
will be required.
B. Vent Components Diagrams (continued)
Figure 15.3 DVP vent components
Term Cap
Minimum
Effective Length
Maximum
Effective Length
Trap1
3-1/8 in. 4-5/8 in.
79 mm 117 mm
Trap2
5-3/8 in. 9-3/8 in.
137 mm 238 mm