Hearth and Home Technologies Cyclone-Cust Indoor Fireplace User Manual


 
Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08 21
Figure 8.3
A
B
Figure 8.4
Figure 8.5 Seams
Note: Make sure that the seams are not aligned to prevent
unintentional disconnection.
INCORRECT
CORRECT
Assembling Minimum Installations (MI) Sections
MI sections are non-unitized so that they can be cut to a
certain length. Cut these sections to length from the non-
expanded end (see Figure 8.6). For installations into com-
mercial, multi-family (multilevel exceeding two stories) or
high-rise applications, it is required to seal MI (non-unitized)
pipe with a bead of silicone sealant. Apply to the overlap
of outer pipe sections only.
They can then be attached by rst connecting the expanded
end of the MI inner ue with the inner pipe from the adjacent
pipe section and securing with three screws. The expanded
portion of the MI inner ue must overlap completely with
the unexpanded end of the adjacent pipe section.
The outer ue can then be inserted into the adjacent outer
ue expanded end and attached to the next pipe section
with three screws. The other end of the MI pipe section can
then be attached by tting another pipe section to it and
snapping it together, as normal.
Figure 8.7 Slip Section Pilot Holes
Figure 8.8 Screws into Slip Section
Figure 8.6
Cut from this end
Cut from this end
(inner)
(outer)
Pilot hole
Assembling DVP-12A Slip Sections
The outer ue of the slip section should slide over the outer
ue of the pipe section and into (inner ue) the last pipe
section (see Figure 8.7) .
Slide together to the desired length, making sure that a 1-
1/2 inch outer ue overlap is maintained between the pipe
section and slip section.
The pipe and slip section need to be secured by driving
two screws through the overlapping portions of the outer
ues using the pilot holes (see Figure 8.8).
This will secure the slip section to the desired length and
prevent it from separating. The slip section can then be
attached to the next pipe section.
If the slip section is too long, the inner and outer ues of
the slip section can be cut to the desired length.