NOTE:
These are approximate settings, and will vary with type of wood or chimney draft. Due to altitude and other environmen-
tal circumstances, this operation information is a guideline only. Similar burn rates may be obtained using other settings unique
to your situation.
There are many ways to build a fire. The basic principle is to light easily-ignitable tinder or paper, which ignites
the fast burning kindling, which in turn ignites the slow-burning firewood. Here is one method that works well:
1. Place several wads of crushed paper on the firebox floor. Heating the flue with slightly crumpled newspaper before
adding kindling keeps smoke to a minimum.
2. Lay small dry sticks of kindling on top of the paper.
3. Open Start-Up Air Control and Primary Air Control fully.
4. Make sure that no matches or other combustibles are in the immediate area of the stove. Be sure the room is adequately
ventilated and the flue unobstructed.
5. Light the paper in the stove. NEVER light or rekindle stove with kerosene, gasoline, or charcoal lighter fluid; the results can
be fatal.
6. Once the kindling is burning quickly, add several full-length logs 3” (76mm) or 4” (102mm) in diameter. Be careful not to
smother the fire. Stack the pieces of wood carefully: near enough to keep each other hot, but far enough away from each
other to allow adequate air flow between them.
7. When ready to reload the stove, add more logs. Large logs burn slowly, holding a fire longer. Small logs burn fast and hot,
giving quick heat.
8. Adjust the Start-Up Air Control and Primary Air Slide Control; the more you close down (slide right) the Primary Air Slide Con-
trol, the lower and slower the fire will burn. The more you open (slide left) the Primary Air Slide Control, the more heat will be
produced. The Start-Up Air Control is only used for the first 5 to 15 minutes.
As long as there are hot coals, repeating steps 7 and 8 will maintain a continuous fire throughout the season.
NOTE: The special high temperature paint that your stove is finished with will cure as your stove heats. You will notice an odor
and perhaps see some vapor rise from the stove surface; this is normal. We recommend that you open a window until the
odor dissipates and paint is cured.
NOTE: Stove should be run full open for 15 minutes a day to keep air passages clean.
WARNING! ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR
CLOSED AND LATCHED EXCEPT DURING START-UP AND RE-FUEL-
ING OR WHEN USING FIRESCREEN.
WARNING! DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR
IS UNLATCHED OR WHEN USING THE FIRESCREEN. UNSTABLE FIRE-
WOOD COULD FALL OUT OF THE FIREBOX CREATING A FIRE HAZARD
TO YOUR HOME.
CAUTION: Before lighting your first fire in the stove: 1) Make certain that the baffle is correctly posi-
tioned. It should be resting against the rear support; 2) Follow instructions on page 26 for cleaning
plated surfaces, and; 3) Remove all labels from glass front.
BUILDING A FIRE
CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar
liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater
while it is in use.
For maximum operating efficiency with the lowest emissions, follow these operating procedures:
1.
Regardless of desired heat output, when loading stove, burn your stove with both air controls wide open for 5 to 15 minutes.
2.
Regulate burn rate (heat output) by using the Primary Air Slide Control (center under ashcatcher). The Start-Up Air Control
(on the right) is used for initial start-up and reloading.Refer to Figure 21A on page 21.
3. Heat output settings: Following 5 to 15 minutes of burning with controls wide open (see #1 above):
4. Only Burn dry, well-seasoned wood.
HEAT OUTPUT SETTINGS
WARNING: Do not operate with Start-Up Air
Control in the open position in excess of 15
minutes! Risk of extreme temperatures! Pro-
longed operation of this stove with the Start-
Up Air Control in the open position may cause
the combustible materials around the stove to
exceed safe temperature limits.
*Primary Control
Slide RIGHT to Stop
1/8” to 1/4” open
1/4” - 1.0” open
Fully open-slide LEFT
BTU / Hr
Below 10,000
10,000 - 15,000
15,000 - 30,000
Maximum Heat
Start-Up Air Control
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes