Hearth and Home Technologies CUMBGAP-PMH Indoor Fireplace User Manual


 
R
Page 10
September 1, 2008
Cumberland Gap Wood Stove
7006-188E
The flue collar is reversible for either a top or rear venting
installation. The unit is shipped with the flue collar in the top
vent position.
ACCESSORY HORIZONTAL FLUE SHIELD
Part HTSHLD-7006
IS REQUIRED ON ALL HORIZONTAL INSTALLATIONS.
Figure10C
CONVERTING COLLAR FOR REAR VENT INSTALLATION
1.
Lift off cast top. Remove 4 Phillips head screws from the
heat shield and discard heat shield. See circled areas in
Figure 10A.
2. Remove 4 Phillips head screws from the rear shield, 2
on each side, lift rear heat shield off and set aside.
3.
Remove 1 bolt from each side of the flue collar
using a
Phillps head screwdriver and 7/16 wrench.
4. Turn flue collar to horizontal position. Inspect sealant to
ensure a leak free application. Re-attach bolts.
5. Re-attach the rear heat shield.
6. Attach required accessory Horizontal Flue Shield with
screws provided. Figure 10B
7. Place cast top on the unit. See Figure 10C for completed
view.
REVERSIBLE FLUE COLLAR
Completed View
Figure 10A
Discard heat
shield
Remove 4 screws and set
rear shield & screws aside
Remove bolts and
rotate flue collar
Rear Heat
Shield
Remove cast top
Figure 10B
Secure
Horizontal Flue
Heat Shield