Hearth and Home Technologies CUMBGAP-PMH Indoor Fireplace User Manual


 
Page 17
Cumberland Gap Wood Stove
R
September 1, 2008
7006-188E
Items Needed for Installation: 4 in. (102mm) diameter flex
pipe in the length as required for your installation; Phillips
screwdriver; Silicone sealant; Drills and saws necessary for
cutting holes through the wall or flooring in your home.
Included in Kit: 2 cable ties; oustide air termination cap;
mounting screws (Discard the remaining parts).
OUTSIDE AIR KIT INSTALLATION
Part 831-1780
NOTE: If you plan to install the optional blower AND
the outside air kit, complete installation of
the outside air kit FIRST.
1. Remove three Phillips head screws from rear of unit.
2. Using the Phillips head screws, attach blower to lower
rear of stove, as shown.
3. Plug blower cord into a grounded outlet. Do not remove
ground prong from plug. Route power cord to avoid
heat from the stove, or other damage. Do not route
cord under or in front of appliance.
4. Adjust the blower speed control to the desired speed.
INSTALLATION OF OPTIONAL BLOWER, Part 831-1701
The blower is shipped fully assembled and ready for installation.
*ADJUSTING THE BLOWER SPEED CONTROL,
If Necessary
NOTE: When the speed control is turned clockwise, it will click
on to high speed. Turn the speed control clockwise to
decrease the speed. At full clockwise, the blower should
blow gently, but should not stop.
1. With the unit plugged in, turn the speed control knob to
slow (full clockwise).
2. With a small screwdriver, adjust the blower speed by
turning the adjustment mechanism through the hole on
the side of the speed control.
3. Adjust the speed so the blower runs slowly, but does
not stop. Turn clockwise to slow the blower and
counterclockwise to increase the speed.
*The blower speed control for this unit is adjusted
at the factory, and normally does not require further
adjustment.
REAR SHIELD
BLOWER MOUNTING
FLANGE
BLOWER SPEED CONTROL
BLOWER
MOUNTING
FLANGE
REAR
SHIELD
OUTSIDE AIR
TERMINATION CAP
(contains rodent screen)
OUTSIDE AIR
INTAKE
1. Remove all materials from packing box.
2. Mount the flex flange (with pipe fitting extending out),
over the intake air opening at the rear of stove using the
four mounting screws supplied with kit.
3. Cut a 4 inch (102mm) minimum hole in the floor or wall
to accommodate outside air piping. Use 4 inch (102mm)
metal flex or rigid piping to directly connect outside air to
the unit or into vented crawl space. (Do not put flex into
a non-vented crawl space). If using flex tubing attach
cable ties to secure tubing at both ends. Use the supplied
termination cap with a rodent screen. Seal between the
floor or wall and the pipe with silicone to prevent moisture
penetration.