Castile Pellet Insert
C. Full Reline With Outside Air
Outside Air
Termination
at
Chimney Top
Outside Air
through
Rear Wall
Exit through the
Ash Clean-Out of
Masonry Chimney
12” (305mm)
min. below
12” (305mm)
min. above
NOTE; Use metal
plate around
exhaust vent pipe
and seal all edges
with non-flammable
insulation such as
fiberglass, mineral
wool or ceramic.
Do not use high
temperature caulk-
ing materials to
seal any edge to
prevent furture
serviceability.
NOTE: Check clearances carefully for this
type of installation to ensure adequate room
for outside air venting.
Check building codes prior to installation.
Installation MUST comply with local, regional,
state and national codes and regulations.
Consult local building, fire officials or authori-
ties having jurisdiction about restrictions,
installation inspection, and permits.
CAUTION
Figure 14.2
NOTE:
In Canada, only a full reline is
allowed per ULC S-628, ORD ULC C1482.