A tap is provided on the outlet side of the gas control
for a test gauge connection to measure the manifold
pressure. To measure inlet pressure, provisions
must be made to attach a test gauge to the tap
immediately upstream of the gas supply connection
to the fireplace.
The fireplace and its individual shut-off valve must be
disconnected from the gas supply piping system
during any pressure testing of the system at test
pressures in excess of 60 mbar.
If the fireplace must be isolated from the gas supply
piping system by closing an individual shut-off valve,
it must be of the handle-less type.
Pressure requirements for Heat & Glo gas fireplaces
are shown in the table below.
Step 7
Gas Pressure
Requirements
______________________________________________________________
Natural Gas Propane Butane Natural Gas
(G20) (G31) (G30) (G25)
Inlet Pressure 20mbar 37 or 50mbar 30 or 50mbar 25mbar
Manifold Pressure 4-8.7mbar 15.7-25mbar 15.7-25mbar 4-8.7mbar
Gas Rate .54
m
3
/
h
.24
m
3
/
h
.16
m
3
/
h
.54
m3
/
h
Max.Input(NETCV) 10.0 kW 10.0 kW 9.5 kW 8.5 kW
Burner Injector DMS 33 1.8 mm DMS 51 DMS 33
Pilot Injector 51 30 30 51
Step 8
Wiring the
Fireplace
NOTE: Electrical wiring must be installed by a
competent electrician.
For Standing Pilot Ignition Wiring
Appliance Requirements
Optional Accessories
Optional remote control
kits require that 230 VAC
be wired to the factory in-
stalled junction box be-
fore the fireplace is per-
manently installed.
Wall Switch
Position the wall switch in the desired position on a wall. Run a maximum of 780cm
or less length of 0.102 cm diameter minimum wire and connect it to the fireplace
ON/OFF switch pigtails.
!
WARNING: DO NOT CONNECT 230 VAC
TO THE GAS CONTROL VALVE OR THE
APPLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED.