Hearth and Home Technologies 6000TRS-CE Indoor Fireplace User Manual


 
10
AB CDE
106.6cm 55.9cm 100.3cm 143.5cm 203.2cm
*
Figure 2. Fireplace Dimensions, Locations, and
Space Requirements
1”MIN. (2.54cmm)
A
B
D
E
20”
(50.8cm)
C
3
Installing the
Fireplace
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
Step 1
Locating the
Fireplace
NOTE:
Dimensions are
shown with the
sides, back
and/or corners
of the unit
touching the wall.
Clearance Requirements
The top and back of the fireplace are defined by
stand-offs.
The minimum clearance to a perpendicular wall
extending past the face of the fireplace is 7.62cm.
The back of the fireplaces may be recessed into
combustible construction (see Figure 3).
MODEL: 6000TRS-CE RECESSED DEPTH: 54.6cm
Minimum Clearances from the Fireplace to Combustible Materials
Glass
Front
Floor
Back of
Fireplace
Sides of
Fireplace
Top of
Fireplace
Ceiling
91.4cm 0 1.3cm 1.3cm 8.9cm 79cm
Figure 3. Minimum Clearances
Minimum Clearances from the Flue Pipe to Combustible Materials
For Horizontal Sections
For Vertical
Sections
At Wall Firestops
Top Bottom Sides Top Bottom Sides
7.6cm 2.54 cm 2.54 cm 2.54 cm 6.4 cm 1.3 cm 2.54 cm